The best solution for your Problem
Logic UH Flex is a robust solution for both surface cracks and joint cracks. It can effectively create a strong barrier in situations where openings may lead to moisture-related issues between the wall and the foundation.
For inquiries and to request a quote, please don't hesitate
to get in touch with us. At Logic Chemie, our utmost priority is to ensure the
correct and optimal utilization of our products in various technical
applications. By working together, we can unlock the full potential of our
products, leading to the best possible results.
Benefits of our Product
The advanced composition of Logic UH Flex effectively inhibits water evaporation in concrete and provides protection against sulphates, which can cause pressure leading to expansion cracks. Once treated with Logic UH Flex, your surface remains safeguarded against cracking for an extended period.
LOGIC UH FLEX
The expansion of your concrete floor or columns creates a lot of pressure on the surface. Because this expansion shows a lot of movement, cracks appear in the concrete. Logic UH Flex is an elastic sealing mortar that adapts to movement. That means that cracks are easily repaired and your concrete surface is protected by the elasticity of Logic UH Flex.
LOGIC UH FLEX
Cracks in lower and upper Reinforcement in columns Cold joints Dilatation Grating edges Pipe edges structures
LOGIC UH FLEX
To prepare the Logic UH Flex mixture, combine components A and B in a 1:1 mixing ratio, and then mix it with sand. For smaller cracks, simply break open the crack and pour the Logic UH Flex mixture into it. However, for larger expansion cracks, create a wooden form into which the Logic UH Flex mixture can be poured. This form will hold the mixture in place while it dries. After approximately 24 hours, the Logic UH Flex will be dry and you can remove the wooden form.
Begin your repair project by thoroughly examining the surface for any irregularities or damages. Removing all excess material is crucial to ensure a pristine and ready surface for Logic UH FLEX application, which significantly boosts the repair's efficacy.
Accurate Surface Marking and Concrete Excavation
Carefully delineate the area requiring treatment. Employ a concrete cutting machine for precise removal within the marked zone, thus setting the stage for an effective Logic UH FLEX application.
Create the Logic UH FLEX mix by blending Component A and B in equal parts in a construction bucket. Gradually add 9-12 kg of sand to the mix, adjusting based on the sand type. Use 0.5 kg each of Component A and B, and around 9 kg of sand, combining them thoroughly with a construction mixer for a consistent repair mortar.
Pour the ready Logic UH FLEX mortar into the designated area. Let it settle for 30 minutes before adding a fine sand layer on top to optimize the results. For larger cracks, use a wooden form to maintain the mortar's position during the setting process.
Once the Logic UH FLEX mortar is completely dry, proceed to remove any wooden forms used. This marks the successful completion of the surface repair process, ensuring a robust and enduring fix.