FOUNDATION INSULATION OF STRUCTURE

FOUNDATION INSULATION OF STRUCTURE

Topdeck
Wall
Underdeck
Preparing ground
Beams/colums
C E Joints
drainage

Foundation Insulation Bridge

Foundation insulation in bridges is crucial. It regulates temperature, controls moisture, prevents frost heave, reduces energy use, extends lifespan, and enhances safety. It ensures structural integrity, lowers maintenance costs, and promotes sustainability in infrastructure.

Preparing ground

During the construction of a bridge, the initial phase involves meticulous ground preparation. The ground is carefully leveled and compacted, ensuring it becomes perfectly straight and flat. Once the ground is properly prepared, the subsequent step is to securely anchor the beams into the foundation. These sturdy beams form the critical support structure, enabling the bridge to bear the weight of decks and any additional loads placed upon it. This foundational work lays the groundwork for a robust and durable bridge capable of withstanding various stresses and ensuring safe passage for all users.

What is the method of Foundation insulation of structure for Preparing ground of bridge?

Beams/coloms

For optimal bridge construction, it is vital to directly build the beams or columns onto the foundation. This approach ensures a robust adhesion, enhancing the overall strength of the bridge. The beams play a crucial role in supporting the weight and significantly contribute to the bridge's high carrying capacity and safety. By securely anchoring the beams or columns to the foundation, the bridge attains a sturdy foundation, providing the necessary stability and durability for safe and efficient transportation across its span.

What is the method of waterproofing the Beams/coloms of the historical buildings?

Wall

Once the beams are in place, the next step involves adding the walls to the structure. These walls consist of (prefab) concrete surfaces positioned on the sides. Proper insulation of these walls is paramount, as it ensures the long-term health of the bridge and prevents issues like rotting or cracking within the surfaces. Additionally, roof trusses will be securely attached on top of the frame walls, further reinforcing the bridge's structural integrity and creating a resilient and functional bridge for safe passage. Meticulous attention to insulation and construction details guarantees the bridge's durability and longevity, making it a reliable and safe transportation route.

What is the method of Foundation insulation of structure for Wall of bridge?

Underdeck

The underdeck, also known as the bridge's underside when viewed from beneath, serves as a crucial element in the bridge's design. It acts as a receptacle for any water leakage that may occur from the top deck. Consequently, most issues are initially visible in this area of the bridge. When a bridge is constructed over water, moisture may rise and penetrate the underdeck. Thus, employing appropriate insulation becomes vital to safeguard the underdeck from potential rotting and to maintain its structural integrity. Choosing the right insulation ensures the underdeck remains resilient and protects it from the harmful effects of moisture, contributing to the overall longevity and reliability of the bridge.

What is the method of Foundation insulation of structure for Underdeck of bridge?

Topdeck

The top deck, situated above the underdeck, is typically assembled using prefabricated concrete pieces. To ensure a watertight surface, a waterproof coating like epoxy will be applied, preventing any water leakage from the topdeck to the underdeck. These coatings must exhibit strong resistance against chemicals and gases since vehicles, including cars and trucks, will traverse over them. By implementing these measures, the likelihood of moisture-related issues within the concrete is minimized, reducing the risk of corrosion and unsightly rust spots in case of any leakage. This protective approach guarantees the structural integrity and aesthetic appeal of the bridge, ensuring a durable and safe passage for all vehicles crossing over it.

What is the method of Foundation insulation of structure for Topdeck of bridge?

C E Joints

During the construction of a bridge, concrete expansion joints are strategically incorporated between the prefabricated parts. These joints play a crucial role in relieving the pressure caused by movement, thereby preventing cracking of the prefabricated concrete components. By integrating concrete expansion joints, the bridge's lifespan is extended, and the overall infrastructure is strengthened.

To ensure optimal performance, it is imperative to insulate the area surrounding the concrete expansion joint. This insulation acts as a protective barrier, preventing water and moisture from seeping into other parts of the bridge. By safeguarding against water infiltration, potential damage is minimized, and the bridge's durability and structural integrity are further enhanced, leading to a longer-lasting and reliable transportation route.

What is the method of Foundation insulation of structure for concrete expansion joints of bridge?

Drainage

Ensuring proper drainage is essential for the longevity and stability of a bridge structure. To establish an effective foundation for drainage, several key steps should be followed. First, the site should be thoroughly assessed to determine natural drainage patterns and potential water accumulation areas. Proper grading of the ground is crucial to ensure that water flows away from the bridge structure. The foundation should be constructed with materials that resist water infiltration and erosion. Additionally, drainage features like culverts, gutters, and drainage pipes must be incorporated into the design to efficiently direct water away from the bridge. Properly executed foundation work for drainage not only enhances the bridge's durability but also contributes to its safety and overall functionality, making it a critical aspect of bridge construction and maintenance.

What is the method of Foundation insulation of structure for Drainage of bridge?
Biobased products based on Pico Technology

Biobased products based on Pico Technology

Leveraging the power of Pico Technology, which operates at a scale 1000 times smaller than Nano, Logic Isolation offers unparalleled surface protection. This technique penetrates diverse pore sizes, providing exceptional protection and a two-decade warranty. Our solution not only shields materials from moisture but also promotes air flow, enhancing their lifespan. With a commitment to environmental sustainability, we constantly innovate to deliver durable and eco-friendly products.

Products

Logic EX

waterproof

Logic EX

waterproof

Logic Water

waterproof

Logic Water

waterproof

Logic UH

waterproof

Logic UH

waterproof

Logic UH Flex

waterproof

Logic UH Flex

waterproof

Logic UW

waterproof / injection

Logic UW

waterproof / injection

Logic UW FLEX

waterproof / injection

Logic UW FLEX

waterproof / injection

Logic DP

waterproof

Logic DP

waterproof

Logic DS

waterproof

Logic DS

waterproof

Logic S

waterproof

Logic S

waterproof

Logic DP PLUS

waterproof

Logic DP PLUS

waterproof